Photoelectric reading direct drinking water meter
Water Meters

Photoelectric reading direct drinking water meter

The Photoelectric Reading Direct Drinking Water Meter serves DN15–DN25 pipe at Q3 2.5–6.3 m³/h to ISO 4064 Class B (±2% high zone, ±5% low zone) and PN10. It reads the register optically with no dead zone and reports over RS485 or M-Bus at 2400 bps up to 1,000 m.

    The Photoelectric Reading Direct Drinking Water Meter serves DN15–DN25 pipe at Q3 2.5–6.3 m³/h to ISO 4064 Class B (±2% high zone, ±5% low zone) and PN10. It reads the register optically with no dead zone and reports over RS485 or M-Bus at 2400 bps up to 1,000 m.


    Product Overview

    The measuring chamber is a conventional multi-jet rotor, but the reading head is optical. Instead of a reed switch counting pulses, a photoelectric sensor looks at the number wheels and decodes which digit sits in each window. The figure sent to the system is therefore the figure a person would read off the dial, taken without mechanical contact and without a counting step that can slip.

    That removes the two classic failure modes of a pulse output: missed pulses that permanently under-register, and contact wear that eventually stops the output altogether. Reading has no dead zone — the word wheel can rest at any intermediate position and the electronic value still matches the mechanical display.

    Power is drawn only while a reading is taken, so the meter is effectively passive between reads. Where a remote control valve, collector and concentrator are added, the same meter becomes the metering element of an intelligent management system, with the concentrator handling the wide-area link.


    Technical Specifications

    Model DN Q3 (m³/h) Accuracy Pressure Interface Baud / Distance Water Temp Reading
    PDR-15 15 2.5 Class B 1.0 MPa RS485 / M-Bus 2400 bps / 1,000 m 0–40 °C Optical
    PDR-20 20 4.0 Class B 1.0 MPa RS485 / M-Bus 2400 bps / 1,000 m 0–40 °C Optical
    PDR-25 25 6.3 Class B 1.0 MPa RS485 / M-Bus 2400 bps / 1,000 m 0–40 °C Optical

    Indicating Error ±5% from minimum to transitional flow; ±2% from transitional to overload flow
    Reading Method Photoelectric direct read of the number wheels, no dead zone
    Supply Bus-powered during reading only; no standby draw
    Communication RS485 or M-Bus, 2400 bps, up to 1,000 m
    System Components Remote control valve, data collector, concentrator, management software
    Protection Sealed waterproof treatment; anti-magnetic shielding
    Standard Reference ISO 4064 Class B metrology

    Values shown are typical for standard production; Q3 and meter class are confirmed on the type-approval certificate for each order.

    Key Benefits

    1. Optical reading matches the mechanical dial exactly
    2. No dead zone at any word wheel position
    3. No pulse counting, so no cumulative offset can build up
    4. Powered only during the read, with no standby draw
    5. RS485 and M-Bus at 2400 bps over up to 1,000 m
    6. Sealed waterproof body with anti-magnetic shielding

    Applications

    • Municipal water supply — automated reading and billing
    • Direct-drinking systems — hygienic sub-metering in buildings
    • Industrial campuses — process and domestic water accounts
    • Building services — tenant metering in apartments and offices
    • Water treatment plants — permeate and distribution measurement

    Installation & Maintenance

    Install horizontally with the register facing up where the specification allows, keep the pipe full and observe the straight runs. Wire the RS485 or M-Bus line to the collector and confirm the reading matches the dial. Address and poll the meter on the concentrator, test the anti-magnetic response, and inspect the sealing faces at each annual service.


    FAQ

    Q: How does optical reading differ from a pulse meter?
    A: The sensor reads the digits on the register directly, so a missed or double pulse cannot offset the total.

    Q: What accuracy class is it?
    A: ISO 4064 Class B: ±2% from transitional to overload flow and ±5% below the transitional point.

    Q: How far can the bus run?
    A: Up to 1,000 m at 2400 bps over RS485 or M-Bus.

    Q: What pipe sizes are covered?
    A: DN15 to DN25, with Q3 from 2.5 to 6.3 m³/h.