Metal Tube Rotameter
Water Meters

Metal Tube Rotameter

Short Description:

Metal Tube Rotameter is a device that measures the volumetric flow rate of fluid in a closed tube. It belongs to a class of meters called variable-area flowmeters, which measure flow rate by allowing the cross-sectional area the fluid travels through to vary, causing a measurable effect. Features Inpress protection: IP65

Range ratio: Standard: 10:1

Pressure: Standard: DN15~DN50≤4.0MPa, DN80~DN400≤1.6MPa

    Product Detail

    Specification

    Porduct

    Metal Tube Rotameter

    Model

    SUP-LZ

    Range

    Water (20℃) (01~200000) L/h Air (20,0.1013MPa) (0.03~3000) m³/h

    Range ratio

    Standard 10:1       Optional 20:1

    Accuracy

    Standard: 1.5%     Optional:1%       Gas: 1.5%

    Pressure

    standard:DN15~DN50≤4.0MPa DN80~DN200≤1.6MPa Optioanl: DN15~DN50≤32MPa DN80~DN200≤16MPa

    Connection

    Flange,Clamp,Thread, Sanity thread

    Medium temperature

    Standard:-20℃~120℃ PTFE 0℃~80℃ High temp:120℃~450℃ low temp: -80℃~-20℃

    Environment temperature

    Remote type: -40℃~85℃ Pointer type/local alarm type -40℃~100℃

    Power supply

    Standard type: 24VDC two-wire system (4-20) mA (12VDC~32VDC) Alarm type: 24VDC multi-wire system (4-20) mA (12VDC~32VDC) AC type: (100~240) VAC 50Hz~60Hz Battery type: 3.6V@9AH lithium battery

    Load resistance

    RLmax: 600Ω

    Alarm Output

    Upper and lower limit instantaneous flow alarm Local alarm type: upper limit, lower limit or upper and lower limit instantaneous flow alarm (Contact capacity 1A@30VDC) Upper limit and lower limit alarm hold range is a maximum of 60% of range, and the minimum interval between upper and lower limit
    alarms is 10% of range

    Pulse output

    Cumulative pulse output is output of optocoupler signal isolation Darlington tube (internal 24VDC power supply, maximum current
    8mA)

    Ingress protection

    IP65

    image-2-1